• Media type: E-Article
  • Title: A multicentre analytical comparison study of inter-reader and inter-assay agreement of four programmed death-ligand 1 immunohistochemistry assays for scoring in triple-negative breast cancer
  • Contributor: Noske, Aurelia [Author]; Ammann, Johannes Ulrich [Author]; Wagner, Daniel-Christoph [Author]; Denkert, Carsten Michael [Author]; Lebeau, Annette [Author]; Sinn, Peter [Author]; Kreipe, Hans H. [Author]; Sommer, Ulrich [Author]; Baretton, Gustavo Bruno [Author]; Steiger, Katja [Author]; Kiechle, Marion [Author]; Hieke-Schulz, Stefanie [Author]; Flores, Mike [Author]; Roth, Wilfried [Author]; Weichert, Wilko [Author]
  • Published: March 2021
  • Published in: Histopathology ; 78(2021), 4 vom: März, Seite 567-577
  • Language: English
  • DOI: 10.1111/his.14254
  • Identifier:
  • Keywords: immunohistochemistry ; inter-assay agreement ; inter-reader agreement ; programmed death-ligand 1 ; triple-negative breast cancer
  • Origination:
  • Footnote:
  • Description: Aims Studies in various cancer types have demonstrated discordance between results from different programmed death-ligand 1 (PD-L1) assays. Here, we compare the reproducibility and analytical concordance of four clinically developed assays for assessing PD-L1-positivity in tumour-infiltrating immune cells in the tumour area (PD-L1-IC-positivity) in triple-negative breast cancer (TNBC). Methods and results Primary TNBC resection specimens (n = 30) were selected based on their PD-L1-IC-positivity per VENTANA SP142 (<1%: 15 cases; 1-5%: seven cases; >5%: eight cases). Serial histological sections were stained for PD-L1 using VENTANA SP142, VENTANA SP263, DAKO 22C3 and DAKO 28-8. PD-L1-IC-positivity and tumour cell expression (≥1 versus <1%) were scored by trained readers from seven sites using online virtual microscopy. The adjusted mean of PD-L1-IC-positivity for SP263 (7.8%) was significantly higher than those for the other three assays (3.7-4.9%). Differences in adjusted means were statistically significant between SP263 and the other three assays (P < 0.0001) but not between the three remaining assays when excluding SP263 (P = 0.0961-0.6522). Intra-class correlation coefficients revealed moderate-to-strong inter-reader agreement for each assay (0.460-0.805) and poor-to-strong inter-assay agreement for each reader (0.298-0.678) on PD-L1-IC-positivity. Conclusions In this first multicentre study of different PD-L1 assays in TNBC, we show that PD-L1-IC-positivity for SP142, 22C3 and 28-8 was reproducible and analytically concordant, indicating that these three assays may be analytically interchangeable. The relevance of the higher PD-L1-IC-positivity for SP263 should be further investigated.
  • Access State: Open Access