• Media type: Text; Doctoral Thesis; Electronic Thesis; E-Book
  • Title: Human hand neuromechanics for the design of robotic intelligent upper limb prostheses
  • Contributor: Ma'touq, Jumana [Author]
  • Published: Hannover : Institutionelles Repositorium der Leibniz Universität Hannover, 2019
  • Issue: published Version
  • Language: English
  • DOI: https://doi.org/10.15488/5588
  • Keywords: Muskel-Sehnen-Bahnen ; Handkinematik ; musculotendon path ; Handdynamik ; Gelenkwinkel ; Aktivierungsschätzung ; activation estimation ; Hand kinematics ; joint centre of rotation ; hand dynamics
  • Origination:
  • Footnote: Diese Datenquelle enthält auch Bestandsnachweise, die nicht zu einem Volltext führen.
  • Description: Understanding human neuromechanics is the first step in transforming human capabilities and behaviour into smart human-like robotic systems. The aim of this thesis is to develop a human hand neuromusculoskeletal model that serves as a tool in understanding and replicating human behaviour. In this thesis, five models of the human hand are proposed, i.e. skeletal kinematics, skeletal dynamics, musculotendon kinematics, musculotendon dynamics, and muscle activation estimation. The skeletal kinematic model is a 26 degree of freedom model that includes the five digits and the palm arc. It estimates skeletal joint rotational angles from motion tracking data based on mapping functions between surface landmarks and the estimated joint centres of rotation. In the skeletal dynamic model, both the link torque due to gravitational and inertial forces and the passive torque due to the passive joint properties are estimated. The musculotendon kinematic model calculates musculotendon lengths, length change rates, and musculotendon excursion moment arms as a function of joint configuration. The musculotendon dynamic model used is a Hill-type muscle model that predicts the musculotendon forces for given musculotendon lengths, length change rates, and muscle activations. The musculotendon length and its rate of change are obtained from the proposed musculotendon kinematic model while muscle activations are obtained from the proposed muscle activation estimation model. Using this model, muscle activations are optimised by minimising the difference between the torque resulting from the musculotendon dynamic model and skeletal dynamic model. The proposed models were validated either experimentally using a motion tracking system or by comparing model results with available cadaver/experimental measurements taken from the literature. The sub-millimetre difference between measured and estimated surface markers indicates that the proposed skeletal kinematic model and associated identification procedure are consistent and highly ...
  • Access State: Open Access
  • Rights information: Attribution (CC BY)