Footnote:
Hinweis: Link zur Originalpublikation in der Zeitschrift Journal of materials science research URL: http://dx.doi.org/10.5539/jmsr.v3n3p33 DOI: 10.5539/jmsr.v3n3p33 Quelle: Funke H and Gelbrich S and , Ehrlich A and Kroll L (2014) A Fiber-Reinforced Architectural Concrete for the Newly Designed Façade of the Poseidon Building in Frankfurt am Main Journal of Materials Science Research. - Vol 3, No 3 (2014)
Description:
In the course of revitalizing the Poseidon Building in Frankfurt, an energetically optimized façade, made of architectural concrete was developed. The development of a fiber-reinforced architectural concrete had to consider the necessary mechanical strength, design technology and surface quality. The fiber-reinforced architectural concrete has a compressive strength of 104.1 MPa and a 3-point bending tensile strength of 19.5 MPa. Beyond that, it was ensured that the fiber-reinforced high-performance concrete had a high durability, which has been shown by the capillary suction of de-icing solution and freeze thaw test with a weathering of abrasion of 113 g/m² after 28 freeze-thaw cycles and a mean water penetration depth of 11 mm.