• Media type: E-Article
  • Title: Abstract 411: Rapid and sensitive detection of EGFR C797S mutations using a blood-based droplet digital PCR assay
  • Contributor: Edwards, Victoria; Jackson, Leisa; Reese, Jordan; Mellert, Hestia S.; Pestano, Gary
  • Published: American Association for Cancer Research (AACR), 2019
  • Published in: Cancer Research, 79 (2019) 13_Supplement, Seite 411-411
  • Language: English
  • DOI: 10.1158/1538-7445.am2019-411
  • ISSN: 0008-5472; 1538-7445
  • Keywords: Cancer Research ; Oncology
  • Origination:
  • Footnote:
  • Description: <jats:title>Abstract</jats:title> <jats:p>The adoption of third-generation tyrosine kinase inhibitors (TKIs) to treat non-small cell lung cancer (NSCLC) for EGFR positive patient cases has led to the emergence of acquired resistance pathways. Approximately 40% of EGFRT790M-positive NSCLC cases display an acquired mutation of amino acid 797 (C797S) that mediates this resistance, which can develop after a median of 10 months following treatment. The effectiveness of treatment for patients with EGFRC797S may depend on whether the mutation is present in cis or trans with EGFRT790M, the type of sensitizing mutation (EGFRdel19 or EGFRL858R), and previous treatment(s). Patients with EGFRdel19 or EGFRL858R in conjunction with EGFRT790M and EGFRC797S remain resistant to all current targeted therapies. Several fourth-generation inhibitors are in development but have yet to be validated in clinical trials. We have developed a blood-based test that can detect two of the most common C797S nucleotide mutations (T&amp;gt;A and G&amp;gt;C) in cis or trans with EGFRT790M using the droplet digital PCR (ddPCR) technology and assays. Analytic sensitivity and specificity were assessed using synthetic DNA designed to mimic the EGFRC797S variants and their locus detected in the assay. Normal healthy donors as well as reference ddPCR positive and negative NSCLC donor samples were assessed for clinical specificity and sensitivity. Finally, the precision of the assay was evaluated with both clinical and analytical samples. Specifically, we evaluated the assay at high, medium, and low mutation frequencies over three consecutive days, including repeat runs on one day, and with multiple operators. This assay is capable of accurately and precisely detecting multiple EGFRC797S variants and their locus from blood specimens in the clinical laboratory. Consistent with other ddPCR blood-based EGFR variant assays we have developed, the limit of detection was 0.02%for C797S variants detected in both cis and trans with the T790M mutation. Once validated, the EGFR C797S assay described here may be of utility in diagnosing patients who have developed resistance to osimertinib.</jats:p> <jats:p>Citation Format: Victoria Edwards, Leisa Jackson, Jordan Reese, Hestia S. Mellert, Gary Pestano. Rapid and sensitive detection of EGFR C797S mutations using a blood-based droplet digital PCR assay [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2019; 2019 Mar 29-Apr 3; Atlanta, GA. Philadelphia (PA): AACR; Cancer Res 2019;79(13 Suppl):Abstract nr 411.</jats:p>
  • Access State: Open Access