• Media type: E-Article
  • Title: Combining primary and sulcus piggyback IOLs for the correction of a spherical-cylindrical defect in an eye with abnormal cornea
  • Contributor: Franco, Fabrizio Gaetano Saverio; Nicolosi, Cristina; Vicini, Giulio; Grasso Cannizzo, Piero; Virgili, Gianni; Giansanti, Fabrizio
  • imprint: SAGE Publications, 2023
  • Published in: European Journal of Ophthalmology
  • Language: English
  • DOI: 10.1177/11206721211037824
  • ISSN: 1120-6721; 1724-6016
  • Keywords: Ophthalmology ; General Medicine
  • Origination:
  • Footnote:
  • Description: <jats:sec><jats:title>Introduction:</jats:title><jats:p> Piggyback IntraOcular Lenses (IOLs), or supplementary secondary implant lenses, have been developed to provide a sufficient dioptric power in eyes with high refractive defects, which are not fully correctable after cataract surgery with single IOL in the range of powers available. These lenses can also be used for the correction of refractive errors that occurred for a wrong choice of the IOL power after cataract surgery. </jats:p></jats:sec><jats:sec><jats:title>Case description:</jats:title><jats:p> We report the case of a complete refractive success obtained in a patient with an abnormal cornea, with a central stable ectasia, with thinning, high myopic astigmatism and cataract, obtained with the implant of a primary posterior chamber IOL at the time of cataract surgery and a subsequent implant of a secondary piggyback, sulcus-based customized toric IOL (Camellens FIL 622-2 Toric Monofocal IOL, Soleko, Rome, Italy). </jats:p></jats:sec><jats:sec><jats:title>Conclusions:</jats:title><jats:p> This brief report demonstrates the utility of combining primary and piggyback IOLs implant for the correction of a complex spherical-cylindrical refractive defect in a case of abnormal cornea and cataract. </jats:p></jats:sec>