• Media type: E-Article
  • Title: Intrafractional prostate motion during external beam radiotherapy monitored by a real‐time target localization system
  • Contributor: Tong, Xu; Chen, Xiaoming; Li, Jinsheng; Xu, Qianqian; Lin, Mu‐han; Chen, Lili; Price, Robert A.; Ma, Chang‐Ming
  • imprint: Wiley, 2015
  • Published in: Journal of Applied Clinical Medical Physics
  • Language: English
  • DOI: 10.1120/jacmp.v16i2.5013
  • ISSN: 1526-9914
  • Origination:
  • Footnote:
  • Description: <jats:p>This paper investigates the clinical significance of real‐time monitoring of intrafractional prostate motion during external beam radiotherapy using a commercial 4D localization system. Intrafractional prostate motion was tracked during 8,660 treatment fractions for 236 patients. The following statistics were analyzed: 1) the percentage of fractions in which the prostate shifted <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0001.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0001" /> for a certain duration; 2) the proportion of the entire tracking time during which the prostate shifted <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0002.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0002" />; and 3) the proportion of each minute in which the shift exceeded <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0003.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0003" />. The ten patients exhibiting maximum intrafractional‐motion patterns were analyzed separately. Our results showed that the percentage of fractions in which the prostate shifted by <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0004.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0004" /> off the baseline in any direction for <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0005.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0005" /> was 56.8%, 27.2%, 4.6%, and 0.7% for intact prostate and 68.7%, 35.6%, 10.1%, and 1.8% for postprostatectomy patients, respectively. For the ten patients, these percentages were 91.3%, 72.4%, 36.3%, and 6%, respectively. The percentage of tracking time during which the prostate shifted <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0006.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0006" /> was 27.8%, 10.7%, 1.6%, and 0.3%, respectively, and it was 56.2%, 33.7%, 11.2%, and 2.1%, respectively, for the ten patients. The percentage of tracking time for a <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0007.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0007" /> posterior motion was four to five times higher than that in other directions. For treatments completed in 5 min (VMAT) and 10 min (IMRT), the proportion for the prostate to shift by <jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/acm20051-math-0008.png" xlink:title="urn:x-wiley:1526-9914:media:acm20051:acm20051-math-0008" /> was 4% and 12%, respectively. Although intrafractional prostate motion was generally small, caution should be taken for patients who exhibit frequent large intrafractional motion. For those patients, adjustment of patient positioning may be necessary or a larger treatment margin may be used. After the initial alignment, the likelihood of prostate motion increases with time. Therefore, it is favorable to use advanced techniques (e.g., VMAT) that require less delivery time in order to reduce the treatment uncertainty resulting from intrafractional prostate motion.</jats:p><jats:p>PACS number: 87.50.S‐, 87.53.Kn, 87.55.N‐, 87.55.ne</jats:p>
  • Access State: Open Access