• Media type: E-Article
  • Title: Direct chromogenic substrate immuno-capture activity assay for testing of factor VII-activating protease
  • Contributor: Stephan, Sina; Schwarz, Herbert; Haude-Barten, Anja; Sidelmann, Johannes J.; Fischer, Bodo; Althaus, Harald; Hahn, Martin; Kappel, Andreas; Ehm, Matthias; Vitzthum, Frank
  • imprint: Walter de Gruyter GmbH, 2011
  • Published in: cclm
  • Language: English
  • DOI: 10.1515/cclm.2011.199
  • ISSN: 1437-4331; 1434-6621
  • Keywords: Biochemistry (medical) ; Clinical Biochemistry ; General Medicine
  • Origination:
  • Footnote:
  • Description: <jats:title>Abstract</jats:title> <jats:p> <jats:bold>Background:</jats:bold> The Marburg I (MRI) single nucleotide polymorphism (SNP) of the factor VII-activating protease (<jats:italic>FSAP</jats:italic>) gene has been associated with thrombophilia and atherosclerotic disease. PCR is used to detect the SNP. Also, the specific FSAP activity to cleave single-chain urokinase-type plasminogen activator (scu-PA) serves as a surrogate for PCR testing. Development of further assays is indicated in order to increase testing opportunities for future studies.</jats:p> <jats:p> <jats:bold>Methods:</jats:bold> A direct chromogenic substrate immuno-capture activity assay for FSAP (FSAP dcs activity assay) was established. Performance characteristics of the FSAP dcs activity assay were compared to the FSAP scu-PA activity assay.</jats:p> <jats:p> <jats:bold>Results:</jats:bold> The FSAP dcs activity assay detects FSAP activity from 25% to 150% of the norm. Total CVs ranged from 6% to 10% for FSAP wild type samples and 9%–18% for MRI samples. Correlation between the FSAP dcs and scu-PA activity assays was low (R=0.7). The FSAP dcs activity determined the presence of the MRI FSAP alloenzyme with a diagnostic sensitivity and specificity of 100% [95% confidence interval (CI): 89.6%–100%] and 96.2% (95% CI: 93.2%–97.4%), respectively, whereas the specific FSAP dcs activity increased specificity to 99.0% (95% CI: 97.2%–99.6%).</jats:p> <jats:p> <jats:bold>Conclusions:</jats:bold> The specific FSAP dcs activity represents a reliable method for the detection of the FSAP MRI alloenzyme. Due to the limited correlation between the FSAP dcs and scu-PA activity assays, these different measurands may exhibit different utility in research and clinical applications. Thus, the FSAP dcs activity assay can represent a valuable complement or alternative for FSAP testing in future studies.</jats:p>