• Media type: E-Article
  • Title: Applied Strategy to Characterize the Energy Improvement Using PATs in a Water Supply System
  • Contributor: Camilo Rosado, Luis; López-Jiménez, P.; Sánchez-Romero, Francisco-Javier; Conejos Fuertes, Pilar; Pérez-Sánchez, Modesto
  • imprint: MDPI AG, 2020
  • Published in: Water
  • Language: English
  • DOI: 10.3390/w12061818
  • ISSN: 2073-4441
  • Keywords: Water Science and Technology ; Aquatic Science ; Geography, Planning and Development ; Biochemistry
  • Origination:
  • Footnote:
  • Description: <jats:p>Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especially in pressurized water distribution systems, the use of pressure reduction valves (PRVs) increases the water usage efficiency but it decreases the energy consumption efficiency, since the valves dissipate energy that could be recovered. This research presents a proposal of a recovery system based on the installation of pumps used as turbines (PATs). These machines are located in different points of the high-pressure water distribution system in the Valencia Metropolitan System (Spain). An annual estimate of the theoretical recoverable energy as well as the “ideal” pump for each point were proposed. The theoretical recovered energy value was 847,301 kWh/year for a specific analyzed point. Besides, the characteristic curves of the PATs from a selected point were determined, estimating an improvement in the sustainable indexes. The calculus of these green parameters showed that the implementation of this solution caused a reduction in consumed energy of 1.50 kWh/m3.</jats:p>
  • Access State: Open Access