• Medientyp: E-Artikel
  • Titel: Report of the CCQM-K123: trace elements in biodiesel fuel
  • Beteiligte: Kuroiwa, T. [VerfasserIn]; Zhu, Y. [VerfasserIn]; Inagaki, K. [VerfasserIn]; Long, S. [VerfasserIn]; Christopher, S. [VerfasserIn]; Puelles, M. [VerfasserIn]; Porinsky, M. [VerfasserIn]; Hatamleh, N. [VerfasserIn]; Murby, J. [VerfasserIn]; Merrick, J. [VerfasserIn]; White, I. [VerfasserIn]; Saxby, D. [VerfasserIn]; Caciano de Sena, R. [VerfasserIn]; Dominguez de Almeida, M. [VerfasserIn]; Vogl, Jochen [VerfasserIn]; Phukphatthanachai, Pranee [VerfasserIn]; Fung, W.-H. [VerfasserIn]; Yau, H.-P. [VerfasserIn]; Okumu, T. O. [VerfasserIn]; Kang'iri, J. N. [VerfasserIn]; Tellez, J. A. S. [VerfasserIn]; Campos, E. Z. [VerfasserIn]; Galvan, E. C. [VerfasserIn]; Kaewkhomdee, N. [VerfasserIn]; [...]
  • Erschienen: BAM-Publica - Publikationsserver der Bundesanstalt für Materialforschung und -prüfung (BAM), 2017
  • Sprache: Englisch
  • DOI: https://doi.org/10.1088/0026-1394/54/1A/08008
  • Entstehung:
  • Anmerkungen: Diese Datenquelle enthält auch Bestandsnachweise, die nicht zu einem Volltext führen.
  • Beschreibung: The CCQM-K123 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM to assess and document the capabilities of the national metrology institutes (NMIs) or the designated institutes (DIs) to measure the mass fractions of sodium, calcium, potassium, magnesium phosphorous and sulfur in biodiesel fuel (BDF). The National Metrology Institute of Japan (NMIJ) and National Institute of Standards and Technology (NIST) acted as the coordinating laboratories. Results were submitted by 11 NMIs and DIs. The participants used different measurement methods, though most of them used inductively coupled plasma-mass spectrometry (ICP-MS), isotope dilution technique with ICP-MS and inductively coupled plasma-optical emission spectrometry (ICP-OES) with microwave acid digestion. The material was quite challenging and a number of questions were raised at the IAWG meeting. Concerning S, the variation in S results between participants, particularly those using IDMS methods was discussed at the IAWG meeting. BAM, NIST and NMIJ reviewed their experimental conditions, results and/or uncertainty calculations for IDMS. According to the additional evaluation and investigation, the variances between the revised results became smaller than the original one, the revised results were overlapping between IDMS measurements of S content at the k=2 level. It is not possible to calculate a KCRV with values being modified after submission. It was concluded that this KC does not support S measurements. Accounting for relative expanded uncertainty, comparability of measurement results for each of Na, Ca, K, Mg and P was successfully demonstrated by the participating NMIs or DIs. It is expected that sodium, calcium, potassium, magnesium and phosphorus at mass fractions greater than approximately 0.1 mg/kg, 0.1 mg/kg, 0.05 mg/kg, 0.05 mg/kg and 0.1 mg/kg respectively in biodiesel fuel and similar matrices (fuels and oils etc.) can be determined by each participant using the same technique(s) employed for this key comparison ...
  • Zugangsstatus: Freier Zugang