• Medientyp: Konferenzbericht; E-Artikel
  • Titel: Fail Operational Controls for an Independent Metering Valve
  • Beteiligte: Rannow, Michael [VerfasserIn]
  • Erschienen: Dresden: Technische Universität Dresden, [2016]
  • Erschienen in: Volume 3 – Conference: Thursday, March 10
  • Sprache: Englisch
  • RVK-Notation: ZQ 5460 : Fluidik (Hydraulische und pneumatische Regelung; fluidischer Verstärker)
  • Schlagwörter: independent-metering ; fault-tolerant control ; cross-port pressure control
  • Entstehung:
  • Anmerkungen: Quelle: 10th International Fluid Power Conference (10. IFK) March 8 - 10, 2016, Vol. 3, pp. 465-476
  • Beschreibung: As intelligent hydraulic systems with embedded sensors become more ubiquitous, the real or perceived reliability challenge associated with sensors must be addressed to encourage their adoption. In this paper, a fault-tolerant control strategy for an intelligent independent metering valve that allows continued operation if a sensor fails is described. The twin-spool valve example utilizes position sensors to stabilize the spool positions and eliminate hysteresis, and pressure sensors to provide digital pressure compensation, electronic load sensing, and other features. An independent metering valve has redundancy provided by four sensors working together to control the flow into and out of a single actuator. Although two sensors are needed to control the flow through a spool, the controller can be reconfigured to ensure the flow is always controlled on the spool with both sensors working. To accomplish this, the concept of cross-port pressure control is introduced that uses the faulty side of the valve to maintain constant pressure on the non-faulty side. By maintaining a constant pressure, the flow in and out of the actuator are balanced. Experimental results on the boom of a backhoe demonstrate the operation of the fault tolerant control strategy.
  • Zugangsstatus: Freier Zugang
  • Rechte-/Nutzungshinweise: Urheberrechtsschutz