• Medientyp: E-Artikel
  • Titel: Compact microwave cavity for high performance rubidium frequency standards
  • Beteiligte: Stefanucci, Camillo; Bandi, Thejesh; Merli, Francesco; Pellaton, Matthieu; Affolderbach, Christoph; Mileti, Gaetano; Skrivervik, Anja K.
  • Erschienen: AIP Publishing, 2012
  • Erschienen in: Review of Scientific Instruments, 83 (2012) 10
  • Sprache: Englisch
  • DOI: 10.1063/1.4759023
  • ISSN: 1089-7623; 0034-6748
  • Schlagwörter: Instrumentation
  • Entstehung:
  • Anmerkungen:
  • Beschreibung: <jats:p>The design, realization, and characterization of a compact magnetron-type microwave cavity operating with a TE011-like mode are presented. The resonator works at the rubidium hyperfine ground-state frequency (i.e., 6.835 GHz) by accommodating a glass cell of 25 mm diameter containing rubidium vapor. Its design analysis demonstrates the limitation of the loop-gap resonator lumped model when targeting such a large cell, thus numerical optimization was done to obtain the required performances. Microwave characterization of the realized prototype confirmed the expected working behavior. Double-resonance and Zeeman spectroscopy performed with this cavity indicated an excellent microwave magnetic field homogeneity: the performance validation of the cavity was done by achieving an excellent short-term clock stability as low as 2.4 × 10−13 τ−1/2. The achieved experimental results and the compact design make this resonator suitable for applications in portable atomic high-performance frequency standards for both terrestrial and space applications.</jats:p>