• Medientyp: E-Artikel
  • Titel: Management of Jugular Bulb Injury During Transcanal Endoscopic Tympanoplasty
  • Beteiligte: Amorosa, Luca; Molinari, Giulia; Botti, Cecilia; Presutti, Livio
  • Erschienen: Ovid Technologies (Wolters Kluwer Health), 2021
  • Erschienen in: Otology & Neurotology, 42 (2021) 8, Seite e1186-e1187
  • Sprache: Englisch
  • DOI: 10.1097/mao.0000000000003214
  • ISSN: 1531-7129; 1537-4505
  • Schlagwörter: Neurology (clinical) ; Sensory Systems ; Otorhinolaryngology
  • Entstehung:
  • Anmerkungen:
  • Beschreibung: Variable internal jugular vein anatomy is not rare. A high jugular bulb (JB) is reported in 6 to 34% of cases and, it can be jeopardized during middle ear surgery, especially if dehiscent. Its injury represents a threatening complication of ear surgery. In recent years there has been an increasing trend in the use of endoscopic ear surgery for a wide range of otologic procedures, but being a one-hand technique, the management of bleeding still represents a challenge. The aim of this video, http://links.lww.com/MAO/B280 is to report the endoscopic surgical management of internal jugular vein hemorrhage during endoscopic type I tympanoplasty.