• Medientyp: E-Artikel
  • Titel: Automated assessment of immunofixations with deep neural networks
  • Beteiligte: Thiemann, Christian; Klitzke, Britta; Martinetz, Philipp; Grüning, Philipp; Käster, Thomas; Barth, Erhardt; Kramer, Jan; Martinetz, Thomas
  • Erschienen: Walter de Gruyter GmbH, 2022
  • Erschienen in: Journal of Laboratory Medicine
  • Sprache: Englisch
  • DOI: 10.1515/labmed-2022-0078
  • ISSN: 2567-9430; 2567-9449
  • Entstehung:
  • Anmerkungen:
  • Beschreibung: <jats:title>Abstract</jats:title> <jats:sec id="j_labmed-2022-0078_abs_001"> <jats:title>Objectives</jats:title> <jats:p>The reliable evaluation of immunofixation electrophoresis is part of the laboratory diagnosis of multiple myeloma. Until now, this has been done routinely by the subjective assessment of a qualified laboratory staff member. The possibility of subjective errors and relatively high costs with long staff retention are the challenges of this approach commonly used today.</jats:p> </jats:sec> <jats:sec id="j_labmed-2022-0078_abs_002"> <jats:title>Methods</jats:title> <jats:p>Deep Convolutional Neural Networks are applied to the assessment of immunofixation images. In addition to standard monoclonal gammopathies (IgA-Kappa, IgA-Lambda, IgG-Kappa, IgG-Lambda, IgM-Kappa, and IgM-Lambda), also bi- or oligoclonal gammopathies, free chain gammopathies, non-pathological cases, and cases with no clear finding are detected. The assignment to one of these 10 classes comes with a confidence value.</jats:p> </jats:sec> <jats:sec id="j_labmed-2022-0078_abs_003"> <jats:title>Results</jats:title> <jats:p>On a test data set with over 4,000 images, approximately 25% of the cases are sorted out as inconclusive or due to low confidence for subsequent manual evaluation. On the remaining 75%, about 3,000 cases, not even one is classified as falsely positive, and only one as falsely negative. The remaining few deviations of the automated assessment from the classifications assigned manually by experts are borderline cases or can be explained otherwise. As a software running on a standard desktop computer, the Deep Convolutional Neural Network needs less than a second for the assessment of an immunofixation image.</jats:p> </jats:sec> <jats:sec id="j_labmed-2022-0078_abs_004"> <jats:title>Conclusions</jats:title> <jats:p>Assisting the laboratory expert in the assessment of immunofixation images can be a useful addition to laboratory diagnostics. However, the decision-making authority should always remain with the physician responsible for the findings.</jats:p> </jats:sec>
  • Zugangsstatus: Freier Zugang