• Medientyp: E-Artikel
  • Titel: Abstract 9736: Steerable versus Non-Steerable Sheath Technology in Atrial Fibrillation Ablation: A Systematic Review and Meta-Analysis
  • Beteiligte: Mhanna, Mohammed; Beran, Azizullah; Al-Abdouh, Ahmad; Sajdeya, Omar; Barbarawi, mahmoud; Alsaiqali, Mahmoud; Jabri, Ahmad; Al-Aaraj, Ahmad; Alharbi, Abdulmajeed Abdullah; Chacko, Paul
  • Erschienen: Ovid Technologies (Wolters Kluwer Health), 2022
  • Erschienen in: Circulation, 146 (2022) Suppl_1
  • Sprache: Englisch
  • DOI: 10.1161/circ.146.suppl_1.9736
  • ISSN: 0009-7322; 1524-4539
  • Schlagwörter: Physiology (medical) ; Cardiology and Cardiovascular Medicine
  • Entstehung:
  • Anmerkungen:
  • Beschreibung: <jats:p> <jats:bold>Introduction:</jats:bold> Catheter placement and stability are well-known challenges in atrial fibrillation (AF) ablation. As a result, steerable sheaths were developed to improve catheter stabilization and maintain proper catheter-tissue contact. The purpose of this systematic review and meta-analysis is to see if employing a steerable sheath influences procedure outcome. </jats:p> <jats:p> <jats:bold>Method:</jats:bold> We performed a comprehensive literature search for studies that evaluated the efficacy and safety of Steerable Sheaths (SS) compared to Non-Steerable Sheaths (NSS) in AF ablation. The primary outcome was the rate of atrial arrhythmia (AA) freedom by the time of the last follow-up. The secondary outcomes were the procedure-related complications and procedural characteristics. Risk ratio (RR) or the mean difference (MD) and corresponding 95% confidence intervals (CIs) were calculated using the random-effects model. </jats:p> <jats:p> <jats:bold>Results:</jats:bold> A total of 10 studies, including 967 AF patients (mean age: 59.2±11.1 years, 516 patients managed with SS vs. 454 with NSS), were included. SS group showed a higher rate of freedom of AA compared to NSS (RR: 1.19; 95% CI 1.09, 1.29; P &lt; 0.001). Both techniques had similar rate for procedural-related complication (RR: 1.09, 95% CI 0.50, 2.39; P = 0.83). The SS strategy had a shorter procedure time (MD -10.6 (min.), 95% CI -20.97, -0.20; P = 0.05) but comparable fluoroscopic and radiofrequency application times to the NSS group. </jats:p> <jats:p> <jats:bold>Conclusions:</jats:bold> The steerable sheaths for AF catheter ablation not only reduced the total procedure time but also significantly increased the rate of successful ablation while maintaining a similar safety profile when compared to the traditional non-steerable sheaths. </jats:p> <jats:p> <jats:graphic xmlns:xlink="http://www.w3.org/1999/xlink" orientation="portrait" position="float" xlink:href="g9736.jpg" /> </jats:p>
  • Zugangsstatus: Freier Zugang